Page d'accueil   |  A propos de cette collection  |  Aide  |  Effacer       Anglais  |  Français  |  Espagnol  
Document complet
Dérouler chapitre
Etendre sommaire
Préférences
vers la section précédente vers la section suivante

fermer ce livreA Guide to the Development of on-site Sanitation (WHO; 1992; 246 pages)
Afficher le documentPreface
ouvrir ce répertoire et afficher son contenuPart I. Foundations of sanitary practice
fermer ce répertoirePart II. Detailed design, construction, operation and maintenance
ouvrir ce répertoire et afficher son contenuChapter 5. Technical factors affecting excreta disposal
fermer ce répertoireChapter 6. Operation and maintenance of on-site sanitation
Afficher le documentPit latrines
Afficher le documentSimple pit latrines
Afficher le documentVentilated pit latrines
Afficher le documentVentilated double-pit latrines
Afficher le documentPour-flush latrines
Afficher le documentOffset pour-flush latrines
Afficher le documentDouble-pit offset pour-flush latrines
Afficher le documentRaised pit latrines
Afficher le documentBorehole latrines
Afficher le documentSeptic tanks
Afficher le documentAqua-privies
Afficher le documentDisposal of effluent from septic tanks and aqua-privies
Afficher le documentComposting latrines
Afficher le documentMultiple latrines
Afficher le documentOther latrines
ouvrir ce répertoire et afficher son contenuChapter 7. Components and construction of latrines
ouvrir ce répertoire et afficher son contenuChapter. 8 Design examples
ouvrir ce répertoire et afficher son contenuPart III. Planning and development of on-site sanitation projects
Afficher le documentReferences
Afficher le documentSelected further reading
Afficher le documentGlossary of terms used in this book
Afficher le documentAnnex 1. Reuse of excreta
Afficher le documentAnnex 2. Sullage
Afficher le documentAnnex 3. Reviewers
Afficher le documentSelected WHO publications of related interest
Afficher le documentBack Cover
 

Offset pour-flush latrines

An extension of the idea of the pour-flush pan with a water seal is for the pit to be outside the latrine building (Fig. 6.9). The contents of the pan are discharged through a short length of small-diameter pipe or covered channel with a minimum gradient of 1 in 30. PVC, concrete or clay pipes, 100 mm in diameter, are often used, but the diameter may be the same as the water seal (usually 65-85 mm). Masonry or brickwork channels with smooth circular concrete inverts have been adopted in some Asian countries. The channel is covered by precast concrete slabs or by bricks laid transversely across the top (Fig. 6.10). Pipes or channels should project at least 100 mm into the pit.


Fig. 6.9. Offset pour-flush latrine

 

WHO 91428


Fig. 6.10. Brick-covered drain

 

WHO 91429

Generally speaking, an offset pour-flush latrine requires a larger volume of flushing water than a simple pour-flush latrine. The amount of water required depends on the pan design, pipe slope and roughness. As little as 1.5 litres has been recorded as necessary for each flush, but usually considerably more than this is required.

Offset pour-flush latrines are favoured by many because the superstructure can be permanent. When the pit is full, another pit can be dug alongside and the connecting pipe excavated and relaid to the new pit without damaging the superstructure (Fig. 6.11).


Fig. 6.11. Moving the discharge pipe of an offset pour-flush latrine to a new pit

 

WHO 91430

Another benefit is that the toilet can be located inside the house and the pit outside. If this layout is used, care must be taken to allow for movement of the pipe where it passes through the house wall. This can be achieved either by cutting a slot in the wall (Fig. 6.12) so that it does not bear directly on the pipe, or by installing two short lengths of pipe (Fig. 6.13) joining in the centre of the wall. Both systems allow movement of the wall without breaking the pipe. The distance of the pit from the house wall should be not less than its depth, to prevent the load from the wall causing the pit to collapse. If this is not possible, the pit may be located not less than one metre from the wall, provided that the pit is fully lined and the unsupported plan length parallel to the wall does not exceed one metre (Fig. 6.14).


Fig. 6.12. Pipe laid through a hole in an external wall

 

WHO 91431


Fig. 6.13. Pipe fixed in place through a wall

 

WHO 91432


Fig. 6.14. Minimum distance between a pit and the external wall of a house

 

WHO 91433
vers la section précédente vers la section suivante

S'il vous plaît envoyez vos commentaires   Anglais  |  Français  |  Espagnol